污水检查井设置距离标准是多少
1.在工地,不管市政还是小区排水,又或是污水厂,通常设置为40米/个。
1. In the site, whether municipal or residential drainage, or sewage treatment plants, usually set to 40 meters per unit.
2.建筑小区用塑料检查井应用技术规程 CECS227:2007 里面有规定的,200~400的污水管道间距宜为40m,500~700的污水管道间距为60m。
2. The technical specification for the application of plastic inspection wells in residential areas CECS227:2007 stipulates that the spacing of 200-400 sewage pipes should be 40 m and that of 500-700 sewage pipes should be 60 M.
3.根据您提供的参数,污水检查井的距离应在20-30米间距为好。
3. According to the parameters you provide, the distance between the sewage inspection wells should be 20-30 meters.
4. 圆形的和矩形的扇形的,标准都不一样,一般都是在管道交叉,转折,每隔一定距离等,一般在30m左右。
4. Circular and rectangular fan-shaped, the standard is different, generally in the pipeline intersection, turning, every certain distance, etc., generally around 30 meters.
从以上说法来看还是很值得商榷的。有设计图纸的,按设计设置距离标准,简单有效,个人也改变不了,不按图纸做,结果是不能通过验收。
From the above point of view, it is still worth discussing. If there are design drawings, the distance standard is set according to the design, which is simple and effective, and can not be changed by individuals. If the drawings are not made according to the drawings, the result can not pass the acceptance test.
当然很多小工程没有清晰图纸,此时需要一定的经验处理。可以参照塑料检查井应用技术规程,按型号大小来设置间距:200-400的设置间距应为40米/个,500-700的设置间距应为60米/个。
Of course, many small projects do not have clear drawings, which need some experience at this time. guanl.37ix.com.cn jianchaj.37ix.com.cn gangsug.37ix.com.cnboluoji.07858.netkongzhifa.89ix.comboliji.89ix.comAccording to the technical regulations of plastic inspection wells, the spacing can be set according to the size of the model: the spacing of 200-400 should be 40 meters per unit, and the spacing of 500-700 should be 60 meters per unit.